Publication Date: 8/17/2026
Share
Print
|
||||||
11 - Technical Records SwitchesACPNIMPORTDETAILWhen set to Yes and performing an A/C Initial Template Load import, the import will contain 5 unique P/N Controls per part number. When set to No and performing an A/C Initial Template Load, the import will not contain 5 P/N Controls per part number. CPCPVALIDTRANCODEWhen set to Yes, in the Corrosion Damage Repair window the system will filter the Damage Section, Station, and Stringer fields by A/C Type/Series. When set to No, in the Corrosion Damage Repair window the system will not filter the Damage Section, Station, and Stringer fields by A/C Type/ Series. DEFECTDEFAULTSORTWhen the switch is set to Yes, the user is able to set a default sort. When the user exits the Defect Report window, and enters the window again, the default sort remains. When set to No, the user is not able to save a default sort. DEFEXPRESSWhen set to Yes, when the user creates a new defect via the New Detail button, the New Express window will open. When set to No, when the user creates a new defect via the New Detail button, the New Detail window will open. DEFRPSCHWhen set to yes, the First Schedule of the Defect Report, Defer Schedule will filter to the Repeat Schedule. The system will validate the Repeat Schedule upon saving the Defect. The associated E/C on the First Schedule will not filter to the Repeat Schedule of the Defer Schedule. When set to No, the First Schedule of the Defect Report, Defer Schedule will not filter to the Repeat Schedule. DEFSTATIONWARNWhen set to Yes, there will be a soft warning upon entering an invalid Station that does not exist in the system in the Defect Report, General, Resolution, and Troubleshooting tabs, thus notifying the user of the Station being invalid, but still allowing the Defect Report to be saved. When set to No, there will be a hard warning upon entering an invalid Station that does not exist in the system in the Defect Report, General, Resolution, and Troubleshooting tabs, thus preventing the record from being saved. LOCKDEFFIELDSWhen set to Yes, the Defer To Schedule fields of a Deferred Defect Report cannot be edited once a Concession is applied to the Defect. These Defer fields can be edited up until a Concession is created for the Defer. When set to No, the Defer To Schedule fields of a Deferred Defect Report can continue to be edited after a Concession is applied to the Defect. MANBBRIIRESWhen set to Yes, the Buy Back or RII Yes/No radio buttons will be mandatory upon saving the information in the Defect Report Detail Resolution and Troubleshooting tabs. Upon selecting the Buy Back or RII Yes/ No radio button, the Buy Back or RII radio buttons and the Inspected By field also become mandatory. When set to No, these fields are either unavailable or not mandatory in the Resolution tab and the Troubleshooting tab of the defect report. Switch MANDATRII must be set to No, for switch MANBBRIIRES to function correctly. MANDELAYFLDSWhen set to Yes, the Delay Date, Delay Control, Cancellation and Delay Code fields will appear in bold text and will be mandatory upon creating a new Delay record. When set to No, the Delay Date, Delay Control, Cancellation and Delay Code fields will not appear in bold text and will not be mandatory upon creating a new Delay record. This switch affects the creation of a Delay record across the system wherever a Delay record can be created. MAXREQINSMANWhen set to Yes, the system will set a limitation on the number of skilled workers entered into the Men Required field in the Defect Report Detail, Defer tab. When set to No, the system will not set a limitation on the number of skilled workers entered into the Men Required field in the Defect Report Detail, Defer tab. MDDRINNEWITEMWhen set to Yes, a Deferred Defect Report's MDDR number is copied to all subsequent Defect Report Items when the New Item When set to No, a Deferred Defect Report's MDDR number is not copied to all subsequent Defect Report Items. NLAINTRMVRBWhen set to Yes, NLA parts can be installed on an assembly by right-clicking them in the P/N NLA Installation and Removal window. When set to No, NLA parts cannot be installed on an assembly by right-clicking them in the P/N NLA Installation and Removal window. The right-click installation function is deactivated because these parts are not issued. PNCASWOVERRWhen set to Yes, the system will display a soft warning when one or more Override checkboxes are selected in the P/N Control Authorization, General tab. When set to No, the system will save the P/N Control without displaying a soft warning even when one or more Override checkboxes has been selected. PNWOISSUEACMANDWhen set to Yes, a part that is issued to one Work Order cannot be installed for a different Work Order. When set to No, a part that is issued to one Work Order can be installed for a different Work Order. REPRINTFONEWhen set to Yes, a Form-1 print will be generated when a part is removed from an aircraft. Only Removal transactions will trigger this print. When set to No, a Form-1 print will not be generated when a part is removed from an aircraft. REPINTDEFVALIDWhen set to Yes, if the repeat schedule for a Defect is greater than 1, then the system will validate this value. The Ongoing Trouble Shooting checkbox may be deselected, the Repeat Inspection Performed drop down will default to 'Yes', and Log Page and Item number will be mandatory in Defect Reports. When set to No, the system does not validate the repeat schedule for a Defect. This switch setting will override the functionality of switch STATUSTROUBLE. VALGRNDTIMEWhen set to Yes, the system will validate if the aircraft is on ground when a defect is reported. When set to No, the system will not validate if the aircraft is on ground when a defect is reported. |
||||||
| Top of Page |
Publication Date: 8/17/2026
Share
Print
|
|||||