Download Online Help Print

Previous Topic

Next Topic

Book Contents

Book Index

RSTROREPCD - Links Auto Reset on R/O to Repair Code

Links Auto Reset on R/O to Repair Code

Affected Field: w_pn_control_eu

RSTROREPCD1

  

Switch Set to Yes:

When set to Yes, a Repair Order's P/N Control will only be automatically reset when the R/O's Action field matches the P/N Control's Repair Code and the P/N Control's Auto Reset On R/O checkbox is selected. The P/N Control's All Repair Codes checkbox is available in order to make any R/O Action field applicable to the P/N Control.

eMRO_Settings_Yes

 

Notice the P/N Control's Repair Code and All Repair Codes checkbox. When the All Repair Codes checkbox is deselected, the Repair Code field is mandatory.

When the All Repair Codes checkbox is selected, the Repair Code field is not available.

The functionality works as follows. Populate the Repair Code and select the Auto Reset On R/O checkbox.

Create a Repair Order and enter an Action that does not match the P/N Control's Repair Code. Save the R/O.

From the Control tab, notice that the P/N Control is not selected. This indicates that the Control will not be reset because the R/O's Action does not match the P/N Control's Repair Code.

Now return to the General tab and enter the same Action that is listed in the P/N Control's Repair Code. Save the R/O.

From the Control tab, notice that the Control is now selected. This indicates that the Control will be reset because the R/O's Action does match the P/N Control's Repair Code.

Users could override this functionality by selecting the All Repair Codes checkbox via the P/N Control. Notice that the Repair Code field is not available.

From the Repair Order, General tab, enter a different Action then save.

From the Control tab, notice that the Control is selected indicating that it will be reset.

 

Switch Set to No:

When set to No, the Repair Code in the P/N Control window is informational and therefore does not interact with the Action field of the Repair Order. The All Repair Codes checkbox is unavailable in the P/N Control window.

eMRO_Settings_No

 

Notice that the All Repair Codes checkbox is not available and the Repair Code field is not mandatory.

A Repair Order is created with an Action that does not match the above P/N Control's Repair Code.

From the Control tab, notice that the Control is selected indicating that the Control will be reset even though the R/O Action and the P/N Control Repair Code do not match up. The Repair Code is informational.

See Also

Settings Switches

ACFIELDS - A/C Master Make Line No. and Variable Engineering No. (fields) Mandatory

ACTIONPRIORITY - ROS Action Code Priority

ACWGTRAN - Update Config Number for the A/C weight Values History

ATATYPESER - A/C Type/Series ATA Specification Applicability

AUTOAUTHPNSWCONF - Auto authorize P/N Software Configuration

BINCATLINKPNCAT - Bin Category in Bin Master linked to P/N Category

CHOMITPN - Characters to Omit in P/N

CUSTOMNOTIFIC - Customize Recurrent Items Alert Notifications

DEPMNTMD - Make Depreciation Month or Code Mandatory for Rotable and Repairable Parts

DOTNETPFDFJOIN - .NET Framework PDF concatenation

EMAILPN - P/N Interchangeable, Send E-Mail for All Transactions

ETOPSRECNOTIF - Display ETOPS Notification in Extended Format

FINSYSCT - Vendor Master Make Financial Sys Country (field) Mandatory

FINSYSSITE - Vendor Master Make Financial Sys Site Code (field) Mandatory

FINSYSVEND - Vendor Master Make Financial Sys Country (field) Mandatory

GRAVELCONTROL - Gravel Ratio applied for Aircraft Landing on an Unpaved Runway

I_EMPPOS - Employee Position

I_ENAML - Employee Name

JAVAHEAP - Allows User to Set the Maximum Java Heap Size in MB

KFACTROL - Carrying Cost Factor for EOQ Calculation

LOCKDEFAULTLOGIN - Default Login Method Set in INI File

LOCVEND - Vendor Location (field) Mandatory

MELVIAREV - Update MEL Via Revision

NWPNAUTH - New P/N to Authorization

OEWUPD - Operating Empty Weight Auto Update

ONSTPAUTH - One Step Authorization for P/N

OVRPREFERVEN - Override Preferred Vendor When Manufacturer is Updated

PNACCONF - Display Hard Warning Message Upon Deletion of P/N A/C Configuration

PNCATCHN - Allow P/N Category Change without Validation of the Invoice Status

PNDNTSHW - P/N Control Do Not Cascade Show On Report Checkboxes

PNINMFMN - P/N Control Do Not Cascade Show On Report Checkboxes

PNSOFTAUTH - P/N Software to Authorization

PNVENDPOPREF - Multiple P/N Vendors Cannot be Preferred and Have Same Condition

PNVENDROAUTLOC - Auto R/O By Location

PNVENDROPREF - Only Allow One Preferred Vendor for P/N Repair Capability

PN_NHA_EFF - Enable P/N NHA Effectivity Validation

PRINTBARCODE - Print Barcode Scan Interface Sequence and Flag

PROCONTLNHA - Update Prorated Control Initial Times at Schedule Change

REOREQ_1 - Inventory Levels of min/max/reorder of 1/1/1. Reorder Qty of 1

RFACTROL - Replenishment Cost Factor for EOQ Calculation

SHLFRMV - Remove Shelf Life Expiration

SKILLDEFECT - Allow the Exclusion of Certain Skills from Appearing in the Skills

SSVIAFV - System Ship Via From Vendor Instead of Tran Code

SUPERSEDPN - Superseded By Interchangeable Validation

SYSTRANCDBUF - Use System Category Edit Buffer Control

VALIDATENUMERIC - Validate Numeric Range Logic

VALLICDATE - Validate License Date

VATMNDTRY - Vendor Master Make V.A.T. (field) Mandatory

VATVALIDATE - Validate V.A.T. in Vendor Master window

VNDPRCTCATOF - Protect Vendor Q/A Checkboxes

WALLPIN - PIN required at Completion step in W/O Task Card Assignment Workshop

WOCONSUMBC - Enables/Disables Barcode in W/O Control Summary Print

Top of Page Download Online Help Print