Publication Date: 8/17/2026
Share
Print
|
||||||
|
The Called On 1st and Called On Repeat controls are meant to be used together, where an E/C is activated by one E/C (Called On 1st) and then repeated on another E/C (Called On Repeat). When the Called On 1st control is used, the child E/C will be called on to the parent E/C one time only. The Start At field is used to identify at which parent E/C compliance (Completed NO) the child E/C will be called on and complied with the parent E/C.
This control can only be utilized once per E/C.
The following information/options are available in this window: Start At The Start At number indicates at which parent E/C compliance (Completed NO) the child E/C should be called on to receive compliance.
E/C Called On Schedule Exceptions Indicates that there are differences between the child E/C and parent E/C schedules. When the button is selected the system displays the E/C Called On Schedule Exceptions popup window displaying the fields where the schedule values are different.
_____________________________________________________________________________________
Called On 1st example: Using the above parent/child E/C relationship, the child E/C should be called on to the parent E/C at the parent E/Cs 4th compliance, and at that time the child E/C will also be complied with. The parent E/C has been complied with 3 times for A/C 777.
The child E/C has not yet been complied with for A/C 777.
Upon the parent E/C's 4th compliance the child E/C is called on.
The parent E/C receives its 4th compliance for A/C 777.
And the child E/C, called onto the parent E/C's 4th compliance, has also been complied with for A/C 777.
|
||||||
| Top of Page |
Publication Date: 8/17/2026
Share
Print
|
|||||