Publication Date: 8/17/2026 Share Print

Previous Topic

Next Topic

Book Contents

Book Index

11 - Engineering Switches

DONTPRINTTEXT

When set to Yes, the Task Card Item text created through the XML (via TraxDoc import/load) will not be duplicated in the Task Card print.

When set to No, the Task Card Item text created through the XML (via TraxDoc import/load) is printed with the Task Card.

ECAUTHPROT

When set to Yes, Engineering Controls cannot be edited when right-clicked from the Engineering Authorization Explorer window.

When set to No, Engineering Controls can be modified when right-clicked from the Engineering Authorization Explorer window.

Note: Switch ECAUTHPROT has replaced the functionality of switch TCNECAUTHPROT.

ECBLANKCLASSIF

When set to Yes, the Classification field by default is blank when a new Engineering Control is created.

When set to No, the Classification field by default is set to 'Mandatory' when a new Engineering Control is created.

ECRESTRICTVENDOR

When set to Yes, during the Repair Order creation process when entering a P/N with associated E/Cs that have a vendor restriction, the E/Cs will not display in the R/O if the assigned vendor is not listed as the Repair Order vendor for that P/N.

When set to No, during the Repair Order creation process when entering a P/N with associated E/Cs that have a vendor restriction, the E/Cs will display in the R/O even if the assigned vendor is not listed as the Repair Order vendor for that P/N.

NOSELECTEFECTIVITY

The following Note was added:

Note: In TRAX Version 11 and forward, this switch is only functional for Part Number E/Cs, not for Aircraft E/Cs.

SUPERECCANCEL

When set to Yes, the E/C Superseded Date will determine when the status of any effectivity (not already in TERMINATED status) will be updated to CANCEL status.

When set to No, the E/C Superseded Date will not determine when the status of any effectivity (not already in TERMINATED status) will be updated to CANCEL status.

TCAUTHPROT

When set to Yes, Task Cards cannot be edited when right-clicked from the Task Card Authorization Explorer window.

When set to No, Task Cards can be modified when right-clicked from the Task Card Authorization Explorer window.

Note: Switch TCAUTHPROT has replaced the functionality of switch TCNECAUTHPROT.

TCEDITOR

The Task Editor Style but_task_editor_style button allows the user to set up the default configuration for the format of the stylesheet for the Task Card Editor.

Note: This switch is not new in TRAX Version 11.

TCPNNOTREV

When set to Yes, the system will allow the user to edit the Task Card P/N window. The user will be able to add or delete a record, and change the reserve, repair or set to none the status of the P/N.

When set to No, the system will not allow the user to update the Task Card P/N window.

See Also

11 - Engineering

11 - Engineering Module

11 - Engineering Buttons

11 - Engineering Transaction Codes

11 - Engineering Security

Top of Page Publication Date: 8/17/2026 Share Print