Publication Date: 11/17/2026 Share Print

Previous Topic

Next Topic

Book Contents

Book Index

Planning Control 7.4

Planning Control

7.4

Advance Filter Button, via Due List Window

 

The Advance Filter button button allows users to create and apply specific filter criteria that can then be saved for future uses.

 

Configurations Toolbar, via Planning Control

7.4

OOS - When an In/Out of Service Type is specified from the OOS drop-down, only A/Cs with the In/Out of Service Type transaction code (TYPEOUTOFSERVICEEVEN) selected, will be displayed through the Planning windows. This filter is only applicable to the Dashboard and Due List windows.

Note: This functionality is customer specific and may not be available for all users.

 

Dashboard, via Planning Control

7.4

Average Forecasted Utilization - The Schedule Forecasted Utilization displays the actual average flight hours and cycles for each individual A/C in the fleet. This information is calculated from the A/C Schedule Flight window, via the Planning Module in the core application. For more information, refer to the Planning Manual.

Flight Schedule Forecasted Utilization - The Schedule Forecasted Utilization displays the predicted average flight hours and cycles for each individual A/C in the fleet. This information is calculated from the A/C Schedule Flight window, via the Planning Module in the core application. For more information, refer to the Planning Manual.

Note: When switch FLSCHDAYS is set to Yes, the run on flight schedule due date in Planning Control will be based on the A/C Flight schedule and this switch's Config Number field.

 

Due List, via Planning Control

7.4

Sort By - The Sort By field allows users to organize W/O records by A/C, Schedule Date, Remaining Flight Hours, Remaining Flight Cycles, and Remaining Days.

 

E/C, via Due List

7.4

When an E/C is selected, users can view all pertinent information related to an Engineering Control from the E/C Detail. Users can also add an E/C to a Work Order using the New W/O button and the Existing W/O button.

 

Estimation vs Actual, via Resources Window

7.4

Include Line W/Os checkbox - Select the Include Line W/O checkbox to have line maintenance Work Orders included in the Resources view. Line W/Os are not included in the calculation by default.

 

Interactive Planning Window

7.4

W/O Search bar - The search bar provides additional information about the W/O by opening a pop-up window displaying Details, Workscope, Parts, Tools, and W/O Print information.

 

Login, via Planning Control

7.4

SESSIONTIMEOUT - When the switch SESSIONTIMEOUT is set to Yes, the number entered in the Config Number field dictates how long, in minutes, a user can remain inactive before the session expires. The maximum configurable session before the system times out is 480 minutes. When set to No, the number entered in the Config Number field does not affect the user's session. In this case, the system defaults the session timeout to 20 minutes. This switch applies to the Customer Portal, eContent Control, Line Control, Planning Control, Production Control, Shop Control, Visual Check apps.

 

Maint. Operations Board, via Resources Window

7.4

The Maintenance Operations Board is a live dashboard that displays the usage of production resources at main Locations. In the table below, users can view Planned Hours, Adjusted Available Hours, and Planned % for specific Locations and Sites.

 

Parts Tab, via W/O Details Button

7.4

Provided - The following functionality has been added:

Note: Users can change the part requirement's reservation type from the Provided drop-down.

7.4

Picklist Print - Once a Picklist is created for the required parts, the Picklist Print will be generated.

 

W/O Flag, via Due List Window

7.4

W/O - The following functionality has been added:

Note: The Work Order will be highlighted in red if the Due At date is earlier than the W/O's Start Date.

 

Switches

7.4

DEFAULTSHORTAGEPRNT - When the switch DEFAULTSHORTAGEPRNT is set to Yes and a picklist is being created, the Shortage Print Only checkbox will be selected by default in Planning Control. When set to No and a picklist is being created, the Shortage Print Only checkbox will be deselected by default in Planning Control. For more information, refer to the Parts tab or DEFAULTSHORTAGEPRNT in the eMRO Planning Switches training manual.

Topic updated: 5/13/2026 9:12:02 AM

See Also

Planning Control Version 7 Release Handbooks

Planning Control 7.0

Planning Control 7.1

Planning Control 7.2

Planning Control 7.3

Planning Control 7.5

Top of Page Publication Date: 11/17/2026 Share Print