11.5 - Inventory Switches

GREYOUTBINPREF

When set to Yes and the P/N has been set up with preferred bin locations, the Bin field will be automatically greyed out from the following windows:

  • P/N Initial Load
  • Bin Transfer
  • Order Receiving
  • Return To Stock

When set to No, the Bin field will be available regardless of prior preferred bin locations set up for the P/N.

SCRAP/AUTHORIZATION

When set to Yes, the Authorization Process is activated when a Scrap is conducted through the ‘Scrap Code’ Transaction Code and the Scrap Code is mandatory.

When set to No, the Authorization Process is not activated when a Scrap is conducted and the Scrap Code is not mandatory.

TOOLCALCONTROL

When set to Yes, the Tool Calibration Control securities can be utilized to assign or remove security to the Receiving Inspection, P/N S/N Change, P/N Initial Load, Tool Check In, and Scrap functionalities for components with the Tool Calibration Flag selected in the P/N Master.

When set to No, the Tool Calibration Control securities cannot be utilized, and all users will have access to the Receiving Inspection, P/N S/N Change, P/N Initial Load, Tool Check In, and Scrap functionalities for components with the Tool Calibration Flag selected in the P/N Master.

TOOLCHKINLOCPROTECT

When set to Yes, the location selected in the Location field inside the Tool Check-In window cannot be changed by the user.

When set to No, the location in the Location field inside the Tool Check-In window can be selected.

TOOLCKOUTMAN

When set to Yes, the W/O and Task Card fields of a Tool Check Out are mandatory.

Note: This will override the functionality of Switch MKTOWOMD.

When set to No, neither the W/O nor the Task Card fields of a Tool Check Out are mandatory.

Note: With Switch MKTOWOMD set to Yes, the W/O field will be mandatory.

INVCOUNT/BINTRANSFER

When set to Yes, if a Bin Transfer has been completed after a Physical Inventory Generation, the adjustment will be displayed once the Physical Inventory Count has been done.

When set to No, if a Bin Transfer has been completed after a Physical Inventory Generation, the adjustment will not be displayed once the Physical Inventory Count has been done.